ST506/412
The ST506/412 interface requires two cables, one for
control and one for data. The control cable is shared
between the two drives. But each drive has each own data
cable. By twisting some wires on the control cable it
won't be necessary to set the ID for each drive, since
the twist will do the job. Wires 25 to 29 should be twisted
between drive 1 & drive 2.
Controller Drive 2 Twist Drive 1
+--+ +--+ +--+
|::|===================| |============| | <-Pin 1
|::|===================| |============| |
|::|===================| |============| |
|::|===================| |============| |
|::|===================| |=====\/=====| |
|::|===================| |=====/\=====| |
|::|===================| |============| |
+--+ +--+ +--+
Control cable
(to
the Controller)
(to
the Drive 2)
(to
the Drive 1)
34 PIN IDC FEMALE to the Controller.
34 PIN IDC FEMALE to the
Drive 2.
34 PIN IDC FEMALE to the
Drive 1.
|
Controller |
Drive
1 |
Drive
2 |
Wire 1-24 |
1-9 |
1-9 |
1-9 |
Wire 25 |
25 |
29 |
25 |
Wire 26 |
26 |
28 |
26 |
Wire 27 |
27 |
27 |
27 |
Wire 28 |
28 |
26 |
28 |
Wire 29 |
29 |
25 |
29 |
Wire 30-34 |
30-34 |
30-34 |
30-34 |
Data cable
(to
the Controller)
(to
the Drive)
20 PIN IDC FEMALE to the
Controller.
20 PIN IDC FEMALE to the
Drive.
|
Controller |
Drive |
Wire 1-20 |
1-20 |
1-20 |